-
-
اتصل بالوكيل
A simple spectrophotometric method for the determination of bismuth potassium ammonium citrate in the cleaning wastes of industrial equipment using 4-(2'-pyridylazo)-resorcinol is proposed ...
However, bismuth is seldom present in the deposits of a copper-chloride vein type or in a copper-lead-zinc vein type. Porphyry type deposits can have present bismuth. When bismuth is present as a solid solution in the sulphide minerals, it is concentrated in the final products such as copper, lead, and zinc concentrates. FLOTATION:
Adsorption-Spectrophotometric Determination of Bismuth(III) in Ores and Ore Сoncentrates A. N. Chebotarev a, V. P. Dubovyiya, and D. V. Snigura, * aMechnikov National University, Odessa, 65082 Ukraine *e-mail: [email protected] Received May 12, 2017
Bismuth renders brass cold-short, and is similar in this respect to antimony, although the effect is not as marked. Bismuth is a cause of fire-cracks in brass. High brass intended for cold-rolling should not contain over 0.01 per cent, of bismuth. Bismuth produces hot-shortness in brass. Bismuth is a cause of latent fire-cracks in brass.
A rapid, selective, and highly sensitive froth flotation method for the separation and enrichment of ultra trace amounts of bismuth is developed. The bismuth-Arsenazo III complex is concentrated from 1000 mL of aqueous solution into the scum in the presence of …
A method is described for the flotation and determination of sub-microgram levels of bismuth in water. Bismuth(III) in a 1000ml sample of water is coprecipitated with iron(III) hydroxide at pH 4.0±0.2. The precipitate is floated with the aid of a mixed surfactant (sodium dodecyl sulphate and sodium oleate) and small air bubbles, then separated and dissolved in dilute hydrochloric acid. …
Controlled potential electrolytic separation and determination of copper, bismuth, Lead, and tin. Anal. Chem., 23 (12) (1951), pp. 1798-1806. Crossref View in Scopus ... The solvent extraction separation of bismuth and molybdenum from a low grade bismuth glance flotation concentrate. Hydrometallurgy, 96 (4) (2009), pp. 342-348. View PDF View ...
Bismuth oxyiodide (BiOI), as a narrow band gap (∼ 1.9 eV) photoactive material, draws much interests due to various merits, ... Herein, a sensitive and selective PEC aptasensor was applied in the trace CAP determination by plasmonic-sensitized AgNPs/BiOI composites. A series of characterizations were used to analyze the morphology ...
Methods. Bismuth (III) solutions were prepared gravimetrically by dissolving a weighted portion of metallic bismuth or bismuth (III) nitrate in nitric acid of high purity according to GOST 11125-84 [], further purified by distillation in a vacuum unit for low-boiling acid distillation.The content of impurity elements in nitric acid was measured by inductively coupled …
Simultaneous adsorptive stripping voltammetric method for the determination of trace bismuth(III) and cadmium(II) using cupferron as a complexing agent has been optimized.
A sample is siphoned into and drains through the column with the flow rate being kept constant by using a flotation device. Bi in 250 mL of acidified seawater is extracted onto the column in this ...
This work proposes an extraction process for thorough removal of various impurities in crude bismuth.In the process, crude bismuth was pickled with nitric acid, and then the bismuth in the filtrate was extracted into the organic phase by TBP.After scrubbing with a saturated NaNO 3 solution, stripping was carried out by NaOH solution, and a rod-shaped α-Bi 2 O 3 …
1. Introduction. Bismuth, an important eco-friendly metal (Mohan, 2010), has been widely employed in many technological fields (Liu et al., 2016).Its harmless nature made it a viable alternative for metals that are considered less environmentally preferred (Zhan et al., 2015).As a primary source of bismuth, bismuthinite is the only commercially viable mineral …
Download Table | Determination of bismuth in different samples. from publication: Spectrophotometric determination of bismuth in water samples by dispersive liquid-liquid microextraction after ...
A simple and sensitive spectrophotometric determination of bismuth(III) is based on the reaction between bismuth(III) and o-hydroxyhydroquinonephthalein in the presence of …
A flow injection procedure for the determination of bismuth in pharmaceutical products is described. The procedure is based on the formation of an ion-pair between tetraphenylarsonium and the ...
The HG-ETV-MIP-OES method was successfully applied to the determination of bismuth in solid environmental samples (e.g., hair, tissue, leaves, soil, sediment and fly ash) …
Voltammetric method for bismuth determination in environmental water was developed. The method is based on accumulation of the Bi(III)-cupferron complex onto a HMDE. The procedure was applied to the determination of Bi(III) in natural water samples. Interferences from organic matrix have been reduced using Amberlite XAD-7 resin.
Study on Spectrophotometric Method for Determination of Bismuth after Flotation Separation Using Microcrystalline Adsorption System Xin-Rong Wen* and Chang-Qing Tu …
The determination is made in the usual way : 50 c.c. of the prepared solution, which should not carry more than 0.75 milligram nor less than 0.01 milligram of bismuth, are placed in a Nessler tube and the colour compared with that observed in a similar tube containing water and potassium iodide on adding the standard solution of bismuth.
A review of bismuth determination methods has been published [14]. 10.2.1 Dithizone method. With dithizone ... The best results have been obtained with Brilliant Green (flotation with CCl 4 –toluene mixture, dissolution of the separated compound in ethanol, ε = 2.2·10 5) [55].
A method is described for the flotation and determination of sub-microgram levels of bismuth in water. Bismuth(III) in a 1000ml sample of water is coprecipitated with iron(III) hydroxide at pH 4.00.2.
The results for bismuth(III) are shown in Fig. 2. Satisfactory recoveries of bismuth were obtained over the pH-range 1.2-11 for water when the solution was heated. When the solution was not heated, quantitative recoveries of bismuth were obtained in the pH range of 1.2- 3.5, but at pH-values above 4 the efficiency
A method is described for the flotation and determination of sub-microgram levels of bismuth in water. Bismuth(III) in a 1000ml sample of water is coprecipitated with iron(III) hydroxide at pH …
Apart from the surface reactions taking place the electrochemical conditions under which flotation is achieved in aerated solutions seem to dependant on the amount of iron (figure 2.8) in the ...
A new simple and rapid dispersive liquid-liquid microextraction has been applied to preconcentration trace levels of bismuth as a prior step to its determination by spectrophotometric detection. In the proposed method, dithizone was used as a chelating agent, and tetrachloride carbon and ethanol are selected as extraction and dispersive solvent. The optimization …
Yang et al. [3] proposed a process for the recovery of bismuth from a low-grade bismuth glance flotation concentrate by a solvent extraction method using a trialkyl amine extractant. Wang et al ...
The radial view was used for bismuth determination and three replicates were used to measure the analytical signal. Delay time for washing between samples and signal measurement was set to 150 s. High-purity argon (99.995%) was used to sustain plasma as well as a carrier gas.
Summary. A method is described for the flotation and determination of sub-microgram levels of bismuth in water. Bismuth(III) in a 1000 ml sample of water is coprecipitated with iron(III) …
A modified spectrophotometric method using the bismuth phosphomolybdate complex for the determination of phosphorus in coal and coal ash is suggested.
Bismuth xanthates have emerged as promising environmentally friendly alternatives to traditional lead-based stabilizers in PVC processing. This study synthesized trivalent bismuth (propyl and butyl) xanthate complexes using bismuth nitrate pentahydrate and potassium (propyl, butyl) xanthate in an aqueous medium. The complexes were characterized using elemental …
Abstract The paper presents a novel method for the flotation separation of Bi3+ using microcrystalline adsorption system prior to the determination by spectrophotometry. The …
A study of a new type of mercury-free working electrode – the bismuth bulk annular band working electrode (BiABE) – applied for thallium(I) detection via differential pulse anodic stripping voltammetry (DP ASV), preceded by the complexation of interfering ions (Cd 2+, Pb 2+) with EDTA in an acetate buffer (pH 4.5), is reported.The optimisation of experimental …
The flotation of tin and bismuth coprecipitated with thionalide at pH 2- 3 is thus useful for the enrichment of low gg 1-a levels of tin(IV) and bismuth(III) from water and sea ... The procedure for the AAS determination of tin and bismuth after the separation were almost the same as previously reported [3, 4]. Acknowledgements.
electrooxidation of rhodium from intermetallic compound with bismuth and carry out determination of rhodium in a number of non-traditional gold-platinoid minefields. ... Table 2 shows data on the content of rhodium in the quartz-gold-sulfide ore and flotation concentrate of this ore obtained by stripping voltammetry method. MATEC Web of ...
An efficient method for extracting bismuth (Bi 3+) from a hydrochloric acid (HCl) system by cementation with copper (Cu 0) powder was proposed in this work.The thermodynamic properties of cementation were investigated via cyclic voltammetry measurement and thermodynamic calculation.Then, the effects of reaction temperature, Cu 0 /Bi 3+ molar ratio, …